Home > Knowledge > Content

Hydraulic pump installation should pay attention to the problem

Oct 14, 2021

Problems should be paid attention to after installation of hydraulic pump:

(1) Pay attention to the working condition of the new machine within three months

During the working period of the new machine, we should master the working condition to check, such as the maintenance of the machine parts, the screw is not loose, the oil temperature is not abnormal, the hydraulic oil is not quickly deteriorated, and check the use conditions are not in line with the provisions.

(2) Do not add load immediately after starting the hydraulic pump

After the hydraulic pump is started, it must be carried out for a period of time without load idling (about 10 minutes to 30 minutes), especially when the temperature is very low, it must be heated by the car process, so that the hydraulic circuit circulation is normal and then added to the load, and confirm the working condition.

(3) Investigation of oil temperature change

Pay attention to check the change of high and low oil temperature, and find out the relationship between the oil temperature and the external environment temperature, so as to know the capacity of the cooler, the capacity of the oil tank is not compatible with the surrounding conditions, the use of conditions, and the cleaning of the cooling system can also be tracked.

(4) Pay attention to the noise of hydraulic pump

The new hydraulic pump early wear is less, simply affected by bubbles and dust, high temperature bad smooth or overloading conditions, will lead to adverse consequences, so that the hydraulic pump announced abnormal influence.

(5) Pay attention to the display value of the meter class

At any time to investigate the hydraulic circuit pressure gauge display value, pressure switch signal and other oscillation scene and stability, in order to find out as soon as possible the effect of the hydraulic circuit is not normal.

(6) Pay attention to the investigation of the mechanical action (about the refit pump)

Improper design of hydraulic circuit or poor manufacturing of components, in the beginning of the use of the period is not simple to find, so we should pay special attention to the action condition shown in various conditions of use.

(7) Pay attention to the adjustment of each valve

Fully understand the use of pressure control valve, flow control valve and direction control valve, to adjust the scale and limit must pay special attention to, or adjust the fault not only damage and machinery, but also pose a threat to safety.

(8) Check the status of the filter

The filter in the loop should be regularly removed and cleaned up, and check the condition of the filter screen and the adsorbed dirt on the net, analyze the quality, quantity and size, so that the pollution degree can be investigated in the loop, and even deduce the origin of pollution.

(9) Check the change of hydraulic oil regularly

Every one or two months to view the analysis of hydraulic oil deterioration, discoloration and pollution changes, in order to ensure the normal hydraulic transmission preface.

(10) Pay attention to the leakage of the piping part

If the pipe of hydraulic equipment is good or not, it can be seen after a period of time to check whether it is leaking oil and whether the pipe is loose.

(11) Keep an eye out for abnormal phenomena

Abnormal sounds, oscillations or abnormal signals in the supervision system must have their origin. When an abnormal phenomenon is found, it is necessary to immediately find a back and forth road map, and carefully investigate whether the abnormal phenomenon is caused by a temporary fault. Evaluate the need for parking treatment. Lifting pressure, load, temperature, time, start, stop all include possible causes of abnormal phenomena. Usually should be analyzed item by item.


Send Inquiry