1. General principles of hydraulic system fault diagnosis
Correct analysis of faults is the premise of troubleshooting. Most system faults do not happen suddenly, and there is always an omen before they occur. When the omen develops to a certain extent, a fault will occur. The causes of failure are various, and there is no fixed rule to be found. Statistics show that 90% of hydraulic system faults are caused by improper use and management. In order to diagnose faults quickly, accurately and conveniently, it is necessary to fully understand the characteristics and rules of hydraulic faults, which is the basis of fault diagnosis.
The following principles should be followed in troubleshooting:
(1) First of all, to determine whether the working conditions and peripheral environment of the hydraulic system are normal, it is necessary to first find out whether it is the fault of the mechanical part of the equipment or the electrical control part, or the fault of the hydraulic system itself, and at the same time to find out whether various conditions of the hydraulic system meet the requirements of normal operation.
(2) Regional judgment Determine the region related to the fault according to the fault phenomenon and characteristics, gradually reduce the scope of the fault, detect the components in this area, analyze the causes, and finally find out the specific location of the fault.
(3) Master the types of faults for comprehensive analysis According to the final phenomenon of the fault, gradually in-depth to find a variety of direct or indirect possible causes, in order to avoid blindness, must be based on the basic principles of the system, comprehensive analysis and logical judgment, reduce the suspect object gradually approaching, and finally find the fault location.
(4) Fault diagnosis is based on running records and some system parameters. Establish the system operation record, which is the scientific basis to prevent, discover and deal with the failure; The establishment of the equipment operation fault analysis table, which is a highly summary of the use experience, help to make a quick judgment of the fault phenomenon; With certain detection means, it can make accurate quantitative analysis of the fault.
(5) When verifying possible fault causes, generally start from the most likely fault cause or the easiest place to check, which can reduce the workload of installation and disassembly and improve the speed of diagnosis.
2. Fault diagnosis method
At present, the traditional method to find the fault of hydraulic system is logical analysis step by step approaching fault. The basic idea of this method is comprehensive analysis and condition judgment. That is, maintenance personnel judge the cause of failure by experience through observation, listening, touching and simple testing as well as understanding of the hydraulic system. When a hydraulic system fails, there are many possible causes of failure. Using the logical algebra method, the possible fault causes list, and then according to the principle of easy before difficult logic judgment one by one, item by item approximation, finally find out the fault cause and the specific conditions of the fault.
This method requires maintenance personnel to have the basic knowledge of hydraulic system and strong analytical ability in the process of fault diagnosis to ensure the efficiency and accuracy of diagnosis. But the diagnosis process is more complicated, must go through a lot of inspection, verification work, and can only be qualitative analysis, diagnosis of the fault cause is not accurate enough. In order to reduce the blindness and experience of system fault detection and the workload of disassembly, the traditional fault diagnosis method can not meet the requirements of modern hydraulic system.
In recent years, with the development of large-scale hydraulic system, continuous production and automatic control, many modern fault diagnosis methods have appeared. Such as ferrography technology, can be separated from the oil of a variety of abrasive quantity, shape, size, composition and distribution law, timely and accurately judge the wear parts of the system components, form, degree, etc. And can be quantitative pollution analysis and evaluation of hydraulic oil, to achieve online detection and fault prevention. Another example is the expert diagnosis system based on artificial intelligence, which uses computers to imitate the way experienced experts in a certain field solve problems. The fault phenomenon is input into the computer through the man-machine interface, the computer can calculate the cause of the fault according to the input phenomenon and knowledge in the knowledge base, and then output the cause through the man-machine interface, and put forward the maintenance plan or preventive measures. These methods bring broad prospect to hydraulic system fault diagnosis and lay the foundation for hydraulic system fault diagnosis automation. But most of these methods need expensive detection equipment and complex sensor control system and computer processing system, and some of them are difficult to study. It is not suitable for field promotion at present. The following introduces a simple and practical method of hydraulic system fault diagnosis.
2.1 Fault diagnosis system based on parameter measurement
Whether a hydraulic system works normally depends on two main working parameters, namely, whether the pressure and flow are in the normal working state, and whether the system temperature and the actuator speed and other parameters are normal or not. The failure phenomenon of hydraulic system is various, and the failure reason is the synthesis of many factors. The same factor may cause different fault symptoms, and the same fault may correspond to many different causes. For example, oil pollution may cause the hydraulic system pressure, flow, direction and other aspects of the fault, which brings great difficulties to the hydraulic system fault diagnosis.
The fault diagnosis idea of parameter measurement method is such that when any hydraulic system works normally, the system parameters are working near the design and set value. If these parameters deviate from the predetermined value in the work, the system will fail or may fail. That is, the essence of hydraulic system failure is the abnormal change of system working parameters. Therefore, when the hydraulic system fails, it is inevitable that a component or some components in the system have a fault, and it can be further concluded that a point or some points in the loop of the parameters have deviated from the predetermined value. This indicates that if the working parameters of a certain point in the hydraulic circuit are not normal, the system has failed or may fail, and the maintenance personnel need to deal with it immediately. In this way, the fault can be found quickly and accurately on the basis of parameter measurement and logical analysis. Parameter measurement method can not only diagnose system faults, but also forecast possible faults, and this kind of prediction and diagnosis are quantitative, greatly improve the speed and accuracy of diagnosis. This kind of detection is direct measurement, the detection speed is fast, the error is small, the detection equipment is simple, easy to popularize and use in the production site. Suitable for any hydraulic system test. When measuring, there is no need to stop, and no damage to the hydraulic system, almost any part of the system can be detected, not only can diagnose the existing fault, but also can carry out online monitoring, forecast potential fault.
2.1.1 Principle of parameter measurement method
As long as the working parameters of any point required in the hydraulic system circuit are measured and compared with the normal value of the system work, it can be determined whether the working parameters of the system are normal, whether the fault occurs and where the fault is located.
The working parameters in the hydraulic system, such as pressure, flow rate, temperature and so on, are non-electric physical quantities. When the indirect measurement method is used to measure with general instruments, the non-electric quantities must be converted into electric quantities by physical effects first, and then after amplification, conversion and display, the measured parameters can be represented and displayed by the converted electrical signals. From this we can judge whether the hydraulic system has a fault. However, this indirect measurement method requires a variety of sensors, the detection device is more complex, the measurement result error is large, is not intuitive, is not easy to popularize field use.
Through years of teaching and production practice, I designed a simple and practical hydraulic system fault detection circuit. The detection loop is usually connected in parallel with the system to be detected. This connection requires a double ball valve tee set at the measured point, which is mainly used for non-disassembly detection of the system. It is a direct and rapid detection of various parameters required by the hydraulic system, without any sensor, it can simultaneously detect the system of pressure, flow and temperature three parameters, and the speed and speed of the actuator can be calculated by measuring the outlet flow method. For example: as long as the pump outlet and actuator inlet, outlet installation of double ball valve tee, by measuring 1, 2, 3 pressure, flow and temperature values, you can immediately diagnose the fault in the general position (pump source, control transmission part or actuator part). Add parameter detection points to narrow the fault area.
When the system is working normally, the valve 1 is open and 2 is closed. Test the dust cover on the mask to prevent contamination. During detection, as long as the detection loop is connected to the detection port, that is, tighten the thread of the loose joint and open the valve 2. By adjusting valve 1 and relief valve 7 can easily measure the pressure, flow, temperature, speed and other parameters. However, when the system piping is required, the double ball valve tee is configured as a nozzle or elbow joint in the part that needs to test the system parameters.
1,2. Globe ball valve 3,8. Hose 4. Pressure gauge 5. Flowmeter 6. Thermometer 7. Relief valve 9. Filter
2.1.2 Parameter Measurement Methods
Step 1: To measure the pressure, first of all, the hose connector of the detection loop and the double ball valve three-way threaded interface are tightly connected. Open the ball valve 2, close the relief valve 7, cut off the oil return channel, then the pressure value of the measured point can be read directly from the pressure gauge 4 (the actual working pressure of the system).
Step 2: Measure flow and temperature -- slowly loosen the handle of relief valve 7 and then close ball valve 1. Adjust the relief valve 7 so that the reading of pressure gauge 4 is the measured pressure value, and the reading of flowmeter 5 is the actual flow value at the measured point. At the same time, the oil temperature value can be displayed on the thermometer 6.
Step 3: Measure the speed (speed) - no matter the pump, motor or cylinder its speed or speed depends on only two factors, that is, the flow and its own geometric size (displacement or area), so as long as the output flow of the motor or cylinder (input flow to the pump), divided by its displacement or area to get the speed or speed value.
2.2 Examples of parameter measurement method
The following phenomena appear in the debugging of this system: the pump can work, but the pressure of the high pressure pump supplying the mold closing cylinder and the injection cylinder does not go up (the pressure is adjusted to about 8.0Mpa, and cannot be adjusted up again), the pump has a slight abnormal mechanical noise, the water cooling system works, the oil temperature and oil level are normal, and there is oil return.
Possible causes for the fault are as follows:
(1) The relief valve is faulty. Possible causes: Incorrect adjustment, spring yield, blocked damping hole, stuck spool valve.
(2) The electro-hydraulic directional valve or electro-hydraulic proportional valve is faulty. Possible causes: The reset spring is broken, the control pressure is not enough, the slide valve is stuck, the proportional valve control part is faulty.
(3) Hydraulic pump failure. Possible causes: The pump speed is too low, the vane pump stator is abnormally worn, the seals are damaged, a large amount of air enters the pump inlet, and the filter is seriously blocked.
Fault diagnosis method:
(1) Apply the traditional logical analysis stepwise approximation method. It is necessary to analyze, judge and check all the above possible causes one by one, and finally find out the fault cause and the specific component causing the fault. This method diagnosis process is complicated, must carry out a lot of installation, verification work, low efficiency, long time limit, and can only be qualitative analysis, diagnosis is not accurate enough.
(2) Application of fault diagnosis system based on parameter measurement. Only in the system piping, in the pump outlet a, reversing valve b and cylinder entrance c three points set up double ball valve tee, then the use of fault diagnosis and detection loop, within a few seconds can limit the system fault in a certain area and according to the measured parameter value of the fault diagnosis. The detection process is as follows:
(a) Connect the fault diagnosis circuit with the detection port a, open the ball valve 2, loosen the relief valve 7, and then close the ball valve 1. Then the relief valve 7 can be adjusted from the pressure gauge 4 to observe the pump working pressure change, to see whether it can exceed 8.0Mpa and rise to the required high pressure value. If not, it indicates that the pump itself is faulty. If it can indicate that it is not a pump fault, it should continue to detect.
(b) If the pump is not faulty, the fault diagnosis loop is used to detect the pressure change at point b. If the working pressure at point b exceeds 8.0Mpa and rises to the required high pressure, it indicates that the main relief valve is working properly and needs to be tested.
If the relief valve is not faulty, it can be determined whether the reversing valve or proportional valve is faulty by detecting the pressure change at point c.The final failure is caused by serious leakage in the vane pump. After the removal of the pump, it is known that the vane pump stator is abnormal wear due to poor smoothness, causing the increase of internal leakage, so that the system pressure is not high, and it is further found that it is caused by the water leakage of the water cooling system into the oil resulting in oil emulsification and loss of lubrication.
3. Conclusion
Parameter measurement method is a practical and new hydraulic system fault diagnosis method. It is combined with logic analysis method, which greatly improves the rapidity and accuracy of fault diagnosis. First, the measurement is quantitative, which avoids the blindness and empirical nature of individual diagnosis, and the diagnosis results are realistic. Secondly, the fault diagnosis speed is fast, after a few seconds to tens of seconds can measure the accurate parameters of the system, and then the maintenance personnel can get the diagnosis result by simple analysis and judgment. In addition, this method reduces the system installation and disassembly workload by more than half compared with the traditional fault diagnosis method.
This fault diagnosis and detection loop has the following functions:
(1) can directly measure and visually display liquid flow, pressure and temperature, and can indirectly measure pump, motor speed.
(2) The relief valve can be used to simulate the load of the measured part of the system, and the pressure regulation is convenient and accurate; In order to ensure the accuracy of the measured flow, the temperature difference can be directly observed from the thermometer (should be less than ±3℃).
(3) Suitable for any hydraulic system, and some system parameters can be realized without stopping detection.
(4) The structure is light and simple, the work is reliable, the cost is low, the operation is easy.
This detection loop will load device and simple detection instrument together, can be made into a portable detector, measurement fast, convenient, accurate, suitable for field popularization and use. It lays the foundation for automatic detection, prediction and fault diagnosis.