Hydraulic because of its significant advantages, is widely used in mechanical equipment, but because of its low efficiency, is often criticized by people, in some systems, in order to save energy to reduce unnecessary energy loss, the use of accumulator as an auxiliary power source, hydraulic pump can also work gap, to achieve the purpose of energy saving, but sometimes appear, hydraulic pump frequently start and stop, not only can not save energy, On the contrary, it is easy to cause the motor to overheat and premature failure, today, we will talk together, which causes the phenomenon of frequent start and stop of this pump?

GIF cover
To analyze the reasons, we need to understand the working mechanism of this hydraulic system
1. The accumulator is the control logic of pump start and stop in the hydraulic system with auxiliary power source

Some actuators in the hydraulic system have intermittent action, the working time is very short, or the working time of the actuator is not intermittent. Still, the working speed of a working cycle is very different from the application of the accumulator; you can make the pump work, reducing energy consumption.

This hydraulic system is generally set with a pressure switch or pressure relay, the pressure switch according to the needs of the system, set a maximum pressure and minimum pressure, when the system pressure is lower than the set minimum value, the pressure switch triggered, and drive the pump motor to start, the hydraulic pump to the actuator oil at the same time, but also to the accumulator filled with liquid, until the system pressure reaches the set maximum pressure value. The pressure switch triggers the motor to stop, the pump stops supplying oil, and then only the accumulator supplies oil to the actuator. Until the hydraulic oil in the accumulator consumes a certain amount, the system pressure drops to the set minimum pressure, the hydraulic pump starts again under the trigger of the pressure switch, entering the next cycle, and so on
2. Cause analysis of pump start and stop in hydraulic system

According to the above control logic of the drive pump motor, it is not difficult to find that the cause of frequent start and stop of the pump motor is that the time of the system hydraulic oil pressure from the highest pressure value to the lowest pressure value is shorter, that is, the cycle is faster, then the reason for this cycle is faster, that is, the reason for the frequent start and stop of the pump in the hydraulic system;

1) There is leakage in the hydraulic system, resulting in accelerated pressure reduction, poor seal of the check valve, leakage of the hydraulic cylinder, hydraulic valve, pipeline, etc., which can lead to rapid pressure drop in the system

2) When the hydraulic system is designed, the system pressure range (that is, the difference between the highest set pressure and the lowest set pressure) is designed too small, resulting in frequent start and stop of the hydraulic pump
3) The operation time of the hydraulic system is too long, and the accumulator gas leaks, resulting in a significant reduction in the precharge pressure, which results in a decline in the accumulator's energy storage effect

4) When designing the hydraulic system, the selected volume of the accumulator is too small, resulting in frequent start and stop of the pump motor

5) The pressure sensor fails, and the induced pressure error is large, resulting in the wrong motor start and stop.

3. Corresponding solutions

1) Check whether there is leakage in the hydraulic system. If there is, it is necessary to repair or replace the corresponding parts in time

2) According to the hydraulic oil volume required for the operation of the actuator and the size of the accumulator and other parameters, design and calculate a reasonable pressure range, while considering the reasonable leakage of the system

3) Check whether the pre-filled gas pressure of the accumulator is within the reasonable range of design. If there is low pressure, it is necessary to replenish the gas in time.

4) According to the volume of hydraulic oil required for the operation of the actuator, the volume of the accumulator is reasonably designed and selected, so that it can provide sufficient hydraulic energy during the operation of the system and achieve the designed working cycle

5) Use the system pressure gauge or pressure sensor to check whether the pressure switch is operating at the set value, and if necessary, the third party will verify or replace it with a new one.

 